Seismic Risk of Soft Story Residential Building Designed as Infilled Frames

Made Sukrawa, Ida Ayu Made Budiwati

Abstract


Abstract— This study was conducted to determine the seismic risk of a residential building with soft story considering infill wall in the analysis. Four models of 4 story dormitory building were analyzed to evaluate their performances. The first model was the actual building with infill wall at the upper levels and partially open at ground level (partial soft story - M1Pss). In the second model all walls in ground floor were removed (full soft story-M2Fss). A full infill wall at all levels (M3Non-ss) and an open frame model (M4OF) were also created to be compared to the soft story models. All models were loaded with gravity and quake load appropriate for east Bali region and pushover analysis were performed. Results show that the soft story mechanism occurs due to the absence of the infill wall at ground level (M1Pss and M2Fss). In model with distributed wall (M3Non-ss) and open frame model (M4OF) soft story mechanism was not detected. Accordingly, the infill wall should be considered in the analysis of multistory frame to avoid undetected soft story mechanism.


Keywords


Diagonal strut; Infilled frame; Pushover analysis; Seismic risk; Soft story

Full Text:

PDF

References


ASCE, 2006. Minimum Design Loads for Buildings and Other Structures (7-05). American Society of Civil Engineers.

Sigmund, V. and Penava, D., 2012. Experimental Study of Masonry Infilled R/C Frames with Opening. 15th World Conference on Earthquake Engineering.

Tamboli, H.R. and Karadi, U.N., 2012. Seismic Analysis of RC Frame Structure with and without Masonry Infill Walls. Indian Journal Of Natural Sciences, 3(14), pp.976–997.

Firdausy, A.I., Chen, H.-T. and Zacoeb, A., 2014. Seismic Responses of RC Frame With Different Arrangement Of Masonry Infill Wall. Teknologi dan Kejuruan, 37(2), pp.201–214.

Elmalyh, S., Bouyahyaoui, A. and Cherradi, T., 2018. Seismic Behaviour of Reinforced Concrete Frame with Infill Panels. MATEC Web of Conferences, 149, pp.1–6.

Kirac, N., Dogan, M. and Ozbasaran, H., 2011. Failure of weak-story during earthquakes. Engineering Failure Analysis.

Guney, D. and Aydin, E., 2012. The Nonlinear Effect of Infill Walls Stiffness to Prevent Soft Story Collapse of RC Structures. The Open Construction and Building Technology Journal.

Sukrawa, M., 2014. Design Aspect of including Infill Wall in RC Frame Design. Civil Engineering Dimension, 16(1): 24-32

Sukrawa, M. and Budiwati, I.A.M., 2019. Analysis and design methods for infilled frames with confined openings. International Journal of Technology. 10(2): 394-404.

Varum, H., Dumaru, R., Furtado, A., Barbosa, A.R., Gautam, D. and Rodrigues, H., 2018. Seismic performance of buildings in Nepal after the Gorkha earthquake. In: Impacts and Insights of the Gorkha Earthquake.

Asteris, P.G., 2003. Lateral stiffness of brick masonry infilled plane frames. Journal of Structural Engineering.

Esper, P. and Tachibana, E., 1998. Lessons From The Kobe Earthquake. Geological Society Engineering Geology Special Publication.

Yue-Jun, Y., 2018. Soft Story: A Haunting Plague to Old Buildings in Taiwan.

Murty, C.V.R., 2005. Learning Earthquake Design and Construction 22 - Why are short columns more damaged during earthquakes? Resonance – Journal of Science Education, 10(10), pp.88–91.

Federal Emergency Management Agency, 1998. Evaluation of Earthquake Damaged Concrete and Masonry Wall Buildings Basic Procedures Manual (FEMA 306).

Imran, I. and Aryanto, A., 2008. Experimental Study on The Behavior of R/C Frames In-filled With Lightweight Materials Subjected To In-plane Lateral Loads. In: EASEC-11 - Eleventh East Asia-Pacific Conference on Structural Engineering and Construction.

Foytong, P., Boonpichetvong, M., Areemit, N., Teerawong, J., 2016. Effect of Brick Types on Compressive Strength of Masonry Prisms. International Journal of Technology. 7(7): 1171-1178.

Computers and Structures Inc., 2017. CSI Analysis Reference Manual. California, USA.

ACI, 2014. 318-14: Building Code Requirements for Structural Concrete and Commentary. 318-14: Building Code Requirements for Structural Concrete and Commentary.




DOI: http://dx.doi.org/10.52155/ijpsat.v36.1.4841