The impact of noise on the results of automated slice sensitivity profile measurements in computed tomography
Abstract
Keywords
Full Text:
PDFReferences
Kundra, V.; Silverman, P.M. 2003; Impact of multislice CT on imaging of acute abdominal disease. Radiol Clin North Am, 41(6), pp. 1083-1093.
Mahnken, A.H.; Rauscher, A.; Klotz, E.; Mühlenbruch, G.; Das, M.; Günther, R.W.; Wildberger, J.E. 2007: Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT. Eur Radiol, 17(5), pp. 1310-1319.
Anam, C.; Fujibuchi, T.; Budi, W.S.; Haryanto, F.; Dougherty, G. (2018): An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images. J Appl Clin Med Phys, 19(6), pp. 244-252.
Verduna, F.R.; Racinea, D.; Otta, J.G.; Tapiovaara, M.J.; Toroi, P.; Bochud, F.O.; Veldkamp, W.J.H.; Schegerer, A.; Bouwmand, R.W.; Giron, I.H; Marshall, N.W.; Edyvean, S. 2015: Image quality in CT: From physical measurements to model observers. Physica Medica, 31(8), pp. 823-843.
Anam, C.; Fujibuchi, T.; Haryanto, F.; Budi, W.S.; Sutanto, H.; Adi, K.; Muhlisin, Z.; Dougherty, G. (2019): Automated MTF measurement in CT images with a simple wire. Phantom Pol J Med Phys Eng, 25(3), pp. 179-187.
Anam, C.; Arif, I.; Haryanto, F.; Lestari, F.P.; Widita, R.; Budi, W.S.; Sutanto, H.; Adi, K.; Fujibuchi, T.; Dougherty, G. (2021): An improved method of automated noise measurement system in CT images. J Biomed Phys Eng, 11(2), pp. 163-174.
Anam, C.; Adi, K.; Sutanto, H.; Arifin, Z.; Budi, W.S.; Fujibuchi, T.; Dougherty, G. 2020: Noise reduction in CT images using a selective mean filter. J Biomed Phys Eng. 10(5), pp. 623-634.
Goldman, L.W. (2002). The essential physics of medical imaging. Second Edition. Lippincott Williams and Walkins: Philadelphia.
Primak, A.N.; McCollough, C.H.; Bruesewitz, M.R.; Zhang, J.; Fletcher, J.G. (2006): Relationship between noise, dose, and pitch in cardiac multi-detector row CT. Radiographics, 26(6), pp. 1785-1794.
American Assosiation of Physicists in Medicine. (2013). Spesification and acceptance testing of computed tomography scanners. AAPM Report 39, USA.
Seeram, E. (2001). Computed tomography: Physical principles, clinical application and quality control. WB Sounders: Pennsylvania, USA.
BAPETEN. (2018). Uji kesesuaian pesawat sinar-X radiologi diagnostik dan interkonvensional. Regulation of the Head of Nuclear Energy Regulatory Agency of Indonesia, No. 2 of 2018.
Greene, T.C.; Rong, X.J. 2014: Evaluation of techniques for slice sensitivity profile measurement and analysis. J Appl Clin Med Phys, 15(2), pp. 281-294.
Narita, A.; Ohkubo, M.; Fukaya, T.; Noto, Y. (2021): Technical Note: A simple method for measuring the slice sensitivity profile of iteratively reconstructed CT images using a non-slanted edge plane. Med Phys. 48(3), pp. 1125-1130
Jiang, H. (2001): Investigation of the slice sensitivity profile for step‐and‐shoot mode multi‐slice computed tomography. Med Phys, 28(4), pp. 491-500.
Sofiatun, S.; Anam, C.; Zahro, U.; Rukmana, D.; Dougherty, G. (2020). An automatic measurement of image slice thickness of computed tomography. International Conference and School on Physics in Medicine and Biosystems.
Goto, M.; Tominaga, C.; Taura, M.; Azumi, H.; 4 , Sato, K.; 5 , Homma, N.; Mori, I. (2019): A method to measure slice sensitivity profiles of CT images under low contrast and high-noise conditions. Physica Medica, 60(4), pp.100-110.
Feng, X.; Yongming, Z.; Gang, P.; Huizhi, C.; Jingmin, L.; Renqiang, Y.; Shengkun, P.; Huan, T. (2012): Correlation between the tube current and image noise in low-dose chest CT scan. Chinese Journal of Radiological Medicine and Protection. 32(1), pp. 100-103.
Anam, C.; Sutanto, H.; Adi, K.; Budi, W.S; Muhlisin, Z.; Haryanto, F.; Matsubara, K.; Fujibuchi, T.; Dougherty, G. (2020): Development of a computational phantom for validation of automated noise measurement in CT images. Biomed Phys Eng Express, 6, pp. 065001.
Nosratieh, A.; Yang, K.; Aminololama-Shakeri, S.; Boone, J.M. (2012): Comprehensive assessment of the slice sensitivity profiles in breast tomosynthesis and breast CT. Med Phys, 39(12), pp. 7254-7261.
Christianson, O.; Winslow, J.; Frush, D.P.; Samei, E. (2015): Automated technique to measure noise in clinical CT examinations. Am J Roentgenol, 205(1), W93-W99.
Solomon, J.B.; Li, X.; Samei, E. (2012): Relating noise to image quality indicators in CT examinations with tube current modulation. American Journal of Roentgenology, 200(3), pp. 592-600.
Morsbach, F.; Zhang, Y.H.; Martin, L.; Lindqvist C.; Brismar, T. (2019): Body composition evaluation with computed tomography: Contrast media and slice thickness cause methodological errors. Nutrition, 59, pp. 50-55.
DOI: http://dx.doi.org/10.52155/ijpsat.v26.2.3110
Refbacks
- There are currently no refbacks.
Copyright (c) 2021 Elvira Rizqi Widyanti, Choirul Anam, Eko Hidayanto, Mohammad Haekal

This work is licensed under a Creative Commons Attribution 4.0 International License.